# Start SonicDICOM PACS

You can start SonicDICOM PACS using PACS Manager.

# Start SonicDICOM PACS

  1. Make sure that the status of DICOMApp is "Stopped".
  2. Click "Start".

Click Start

  1. "Status Panel" is displayed.
  2. "OK" is displayed in the status field of DICOM Server and Web Server.

DICOM Server and Web Server started successfully

  1. When SonicDICOM PACS is started normally, "Windows Service 'DICOMApp' started succcessfully" will be displayed.

SonicDICOM PACS started successfully

  1. The status of DICOMApp will display "Running".

Make sure that SonicDICOM PACS is running

# If SonicDICOM PACS fails to start normally

If the port to be used by SonicDICOM PACS is already in use by the other software, PACS cannot be started normally. This is due to a port conflict that causes Web Server or DICOM Server of SonicDICOM PACS to fail to start.
"FAILED" is displayed in status field of Server that failed to start.

Check status of server

In this case, you need to change either the port used by the other software, or the port used by SonicDICOM PACS.

Info

The default Port Number of Web Server is "80".
The default Port Number of DICOM Server is "104".

# If Web Server fails to start

Change the port that may be in conflict with another software to another port.

  1. Click the "Server" tab.

Click Server tab

  1. Change "Port Number" of "Web Server".

Change Port Number of Web Server

  1. Click "Save".

# If DICOM Server fails to start

Select DICOM Provider and change the port that may be in conflict with another software to another port.

  1. Click the "Connection" tab.

Click Connection tab

  1. Click DICOM Provider.

Click DICOM Provider

  1. Change "Port Number".

Change Port Number of DICOM server

  1. Click "Save".